Monovalent mode of operation:
Electric heater is not required
The Wikora heat pump system WIKOSOL HPS was designed for the
replacement and modernization of heaters in existing buildings. The system also provides a cost-effective and environmentally friendly alternative for new Buildings.
The air-to-water heat pump ZUBADAN including universal control
UVR 1611 and combi buffer tank WIKOSOL HPS guarantee in combination with the complete System the highest level of efficiency.
System components
The Mitsubishi Electric ZUBADAN is one of the most powerful heat pumps on the market, providing a cost-effective and environmentally friendly alternative for the
replacement and modernization of heaters in existing Buildings. Thanks to the worldwide patented ZUBADAN inverter technology, sufficient heating power is available even at low outside temperatures. The application range is still up to temperatures of -28 °C. Full power is guaranteed down to -15 °C. The over-dimensioning of the devices for heating operation is unnecessary.
Application
Housing and frame are made of sturdy galvanized steel sheets with additional polyester stove enamelling and internal sound insulation.
Weather-protected drive motor, maintenance-free with thermal overload protection.
High performance heat exchanger as evaporator and condenser.
2 years warranty
Advantages
■ Increase the coefficient of performance by up to 70% compared to a conventional non-inverter-controlled compressor
■ Worldwide patented Flash injection to increase the useful cooling capacity and avoid power losses in heating operation at low outside temperatures
■ Operating range up to -28 °C
■ Guaranteed without power loss down to -15 °C
■ Hardly shutdown breaks by the EVU (utility Company) or defrosting phases
■ Low vibration, mounted on vibration dampers with highest Efficiency
■ Torque increase by neodymium magnets to minimize friction losses
Monovalent mode of operation: Electric heater is not required
Description | 8/11Y | 11Y | 14Y | 23Y | |
---|---|---|---|---|---|
Heating capacity min/max | KW | 4,5 – 10,2/12 | 4,5 – 14,0 | 4,5 – 16,0 | 4,5 – 25,0 |
Application outside air temperature | °C | -28 bis +35 | -28 bis +35 | -28 bis +35 | -28 bis +35 |
Height | mm | 1020 | 1350 | 1350 | 1338 |
Width | mm | 1050 | 950 | 950 | 1050 |
Depth | mm | 480 | 330 | 330 | 330 |
Weight | kg | 128 | 134 | 134 | 148 |
Refrigeration connections | mm | 9,52/15,88 | 9,52/15,88 | 9,52/15,88 | 25,4/12,7 |
Sound pressure level | db/A | 45 | 52 | 52 | 60 |
Application
Directly condensing hygiene tank with a generously dimensioned drinking water heat exchanger made of stainless steel of the highest quality.
Integrated high performance stainless steel exchanger.
Oversized condensation exchanger.
On the refrigerant side, copper tubes Ø 16mm or 22mm are available for brazing.
Buffer tank is corrosion protected by paint on the outside.
Insulation
Removable Neopor / fleece insulation for energy efficiency class B or C
Capacity
600, 800, 1000 l
10 years warranty
Advantages
■ High-performance stainless steel exchanger enables excellent bulk flow despite the low drinking water content
■ An oversized condensation exchanger enables an optimal COP value of the heat pump
■ Heat pumps up to 23 kW can be connected
■ Optimal legionella protection
Designation | WIKOSOL HPS 605 | WIKOSOL HPS 805 | WIKOSOL HPS 1005 | |
---|---|---|---|---|
Capacity | Liter | 598 | 830 | 983 |
Max. working temperature buffer | °C | 95 | 95 | 95 |
Max. working pressure DHW-HE / heating water | bar | 10/3 | 10/3 | 10/3 |
Capacity / Surface DHW-heat exchanger | Liter/ m² | ca. 28/4,0 | ca. 32/5,5 | ca. 32/5,5 |
Insulation | mm | 130 [100] | 140 [100] | 150 [100] |
Energy loss | Watt | 80 [113] | 90 [129] | 96 [140] |
Energy efficiency class | B [C] | B [C] | B [C] | |
Dimensions | ||||
Diameter incl. insulation | mm | 910 [850] | 1070 [990] | 1090 [990] |
Diameter tank | mm | 650 | 790 | 790 |
Height storage tank | mm | 1880 | 2008 | 2195 |
Tilting dimension | mm | 1845 | 1960 | 2150 |
Weight (without insulation) | kg | 126 | 149 | 197 |
Connections | ||||
2 sanitary connections | 1 1/2“ | 1 1/2“ | 1 1/2“ | |
4 connection aux boiler flow | 1“ | 1“ | 1“ | |
3 connection aux boiler return | 1“ | 1“ | 1“ | |
1 thermometer | 1/2“ | 1/2“ | 1/2“ | |
1 draining | 1“ | 1“ | 1“ | |
1 plug for electric heater | 1 1/2“ | 1 1/2“ | 1 1/2“ |
[ ] = Data for energy efficiency class C
Advantages
■ Freely programmable through various function modules
■ Can be adapted to any system configuration for boiler room management
■ Interface C.M.I. enables monitoring and operation via LAN or web portal
■ Possibility of displaying an interactive visualization on a notebook, smartphone or tablet
■ C.M.I. App for data display
■ Enlargement of the inputs and outputs by further CAN bus components
■ Program creation with software TAPPS2
2 years warranty
System variants
Components
■ Heat pump Mitsubishi Electric ZUBADAN 8/11 Y
■ Buffer tank WIKOSOL HPS 605
■ Universal control UVR 1611
■ Heat meter
Components
■ Heat pump Mitsubishi Electric ZUBADAN 8/11 Y
■ Buffer tank WIKOSOL HPS 805
■ Universal control UVR 1611
■ Heat meter
Components
■ Heat pump Mitsubishi Electric ZUBADAN 11 Y
■ Buffer tank WIKOSOL HPS 805
■ Universal control UVR 1611
■ Heat meter
Components
■ Heat pump Mitsubishi Electric ZUBADAN 14 Y
■ Buffer tank WIKOSOL HPS 805
■ Universal control UVR 1611
■ Heat meter
Components
■ Heat pump Mitsubishi Electric ZUBADAN 23 Y
■ Buffer tank WIKOSOL HPS 1005
■ Universal control UVR 1611
■ Heat meter
■ | Most powerful heat pump on the market for heating renovation in existing buildings |
■ | Heating cost savings of up to 50% |
■ | In combination with other heat sources over 8,000 euros BAFA funding possible |
■ | Independence from fossil fuels |
■ | Patented Zubadan inverter technology |
■ | Operating range down to -28 °C (Guaranteed without loss of performance down to -15 °C) |
■ | Flow temperatures up to 60 °C |
■ | No additional building renovations necessary |
Monovalent mode of operation: